Q-Logic SN0135524-00 Manuel d'utilisateur Page 147

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 320
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 146
IBM eServer BladeCenter Fibre Channel Switch Module
Timeout Values
QL
OGIC SWITCH INTEROPERABILITY GUIDE PAGE 135
V
ERSION 1.0, MARCH 2003
For the QLogic SANbox2-64, the following displays:
4. From the Switch PropertiesSANbox Manager dialog box Administrative State list, select
offline. Click OK.
5. Re-enter the Switch PropertiesSANbox Manager dialog box (see step 2). Do the
following:
a. In the R_A_TOV box, change the setting to 10000.
b. In the E_D_TOV box, change the setting to 2000.
c. Click OK.
6. Re-enter the Switch PropertiesSANbox Manager dialog box (see step 2). In the
Administrative State list, select Online. Click OK.