Brocade SilkWorm 3900 and SilkWorm 12000 Switches
Timeout Values
P
AGE 48 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Timeout Values
As per FC-SW-2 Fibre Channel standards, set all switches to the following timeout values (TOV)
in order to successfully establish an E-port connection:
R_A_TOV = 10 seconds
E_D_TOV = 2 seconds
This section provides the steps to change these values.
Brocade’s Web Tools
ATTENTION!!
The following steps take the switch offline; therefore, do not perform them on a
switch being managed in-band.
1. Start Brocade’s Web Tools. The Fabric View dialog box displays.
2. From the Fabric View dialog box, click the Administration button.